Oil in water analyzer factory by BOQU Instruments

Sensor wholesale provider with BOQU: It is possible to pinpoint certain pollutants, a particular chemical, and the cause of the contamination by keeping an eye on the quality of the water. Water contamination comes from various causes, including contamination from oil, river and marine disposal, port operations, shipping, and industrial activities; effluent from sewage leaking into the drinking water supply; and agricultural practices (such as using herbicides and fertilizer). Data from routine water quality monitoring and assessments can be used to pinpoint the cause of any imminent problems. Discover a lot more info on https://www.boquinstrument.com/oiw-300p-online-oil-in-water-analyzer.

BOQU conductivity meter and conductivity sensor widely used in global,production capacity has been over 100 000pcs.TDS,Salinity and Resistivity meter use same conductivity sensor in different program.customers should confirm the application and required range before production,because there is many different range for conductivity sensor,such as :ultra pure water: 0~20μS/ cm(K=0.01),pure water is 0~200μS/ cm(K=0.1),drinking water is 200~500μS/ cm (K=1.0)in Shanghai China.max range of BOQU conductivity is 2000ms/cm.max working temperature is 180℃ by toroidal conductivity sensor(inductive conductivity sensor).it’s widely used for power plant,drinking water,waste water,food,Chemical production,Leak detection in heat exchangers,Acid and caustic dilution,Metal finishing, Plating bath control,Parts cleaning and rinsing,Pickling bath control,Waste streams,Semiconductors,Pulp and paper, Black, white or green liquor,Pulp bleaching food processing,Chemical peeling,Sanitisation (CIP),Environmental Wet chemical scrubbers,Cooling towers etc.

Successful aquaculture for fish and shrimp depends on water quality management.the water quality has directly effect on fish living,feed, grow and Reproduction.Fish diseases usually occur after stress from impaired water quality. water quality problems may change suddenly from environmental phenomena (heavy rains, pond overturn etc), or gradually through mismanagement.Different fish or shrimp species have different and specific range of water quality values,usually farmer need to measure temperature, pH, dissolved oxygen,salinity, hardness,ammonia etc.)

Regular Inspection, Maintenance, Calibration, and Testing: Periodically inspect sensors for damage or debris, maintaining clean probes and circuits to avoid false alarms. Regular calibration checks and testing simulations ensure accurate detection and proper functionality. Integrated Systems, Notifications, and Emergency Preparedness: Integrate sensors with intelligent systems for remote alerts and familiarize yourself with different signals. Develop an emergency plan, including actions upon sensor alerts, and keep emergency contacts accessible for a swift response.

BOQU Instruments is leader in water quality sensors and have two factory in Shanghai, production is over 100 000pcs last year, mainly water quality sensors for ph sensors, dissolved oxygen sensor, turbidity sensor, tds sensor, salinity sensor,conductivity sensor,residual chlorine sensor, suspended solid sensor, UV COD sensor, Ion sensor(F-, CL-, Mg2+, Ca2+, NH+). All water quality sensors is production according to ISO9001, and has CE, SGS, FDA certificates.Our water quality sensor can be matched with different brands of water quality meter at home and abroad and after decades of development, our quality has reached world-class, our most customers buy our water quality sensors to replace international brand, such as METTLER TOLEDO, Hamilton and Hach water quatliy meters and water quality sensors. So now many international company ask us to do OEM or ODM for them.

Water sensors utilize diverse sensing mechanisms, each tailored for specific detection purposes: Conductive Sensors – Employing two electrodes separated by a non-conductive material, conductive sensors detect changes in conductivity triggered by water contact. This completion of an electrical circuit prompts an alert, signaling the presence of water. Capacitive Sensors: Emitting an electrical field between two conductive surfaces separated by a non-conductive material, such as plastic, capacitive sensors sense disruptions caused by water. This alteration in the field triggers an alarm, indicating water presence. Optical Sensors: Leveraging infrared LED light, optical sensors detect alterations in the refractive index of the sensor’s housing material upon contact with water. This change prompts an alert, signaling the presence of water. Find many more info on boquinstrument.com.

Environmental Monitoring: Beyond homes and industries, water sensors play a crucial role in environmental conservation. Monitoring water levels in reservoirs, rivers, or dams helps prevent overflows or depletion, contributing to sustainable water resource management. Wireless and Smart Integration: Modern water sensors have embraced wireless connectivity and intelligent integration. Integration with home security systems allows remote monitoring through smartphone applications, providing real-time alerts and enabling homeowners to take immediate action, even when away from home.

Industrial waste water discharge standards are also classified by industries,such as paper industry,oily wastewater from Offshore Oil Development Industry, textile and dyeing waste water,food process,synthetic ammonia industrial waste water,steel industrial,electroplating waste water,calcium and polyvinyl Chloride industrial water,coal Industry,phosphorus industry water pollutant discharge,calcium and polyvinyl chloride process water,hospital medical wastewater,pesticide wastewater, metallurgical wastewater.

Fourth step is distribution ,we have to measure pH,turbidity,hardness,residual chlorine,conductivity(TDS),then we can know the potential risks or threaten to public heath on time.the residual chlorine value should be over 0.3mg/L when be piped out from drinking water plant, and over 0.05mg/L at end of pipe network.turbidity must less 1NTU,pH value is between 6.5~8,5,pipe will be corrosive if pH value is less 6.5pH and easy scale if pH is over 8.5pH.